Date:2009年7月17日 23:16

According to our clients’ feedback, the last version software has a bug that

will focus incorreclty when marking the edge area of the filed. The new version software has fix it.

In addition, we update dynamic focus D/A board to support the digital protocol which is compatible with XY2-100.

Attention please, 

The pin17 (signal SGIN3) is used to select the digital protocol. When this signal is connect to ground, the protocol is compatible with XY2-100, otherwise another protocol is used. Please wire this pin according the type of scanhead.